An open-frame power supply board for OEM enclosure integration, anywhere in the 5–240 W range, arrives as a bare PCB assembly with four mounting holes, a mains connector, an output header and no case. Everything the case would normally take care of — touch protection, fire enclosure, airflow, creepage to your chassis, EMI to the outside world — becomes your job the moment you bolt it in. That is the point of buying open-frame: it is cheaper and smaller than an enclosed supply and it lets you use your own housing. It is also why the supply's datasheet is only half the specification. The other half is what your enclosure does to it.
This article sets out what to get from the board supplier before you cut a mounting plate, how to read a derating curve against your actual thermal situation, what a component-level safety file does and does not cover, and the handful of details that show up during your own product's safety and EMC testing rather than the board's.
What an open-frame board is and what it is not
Suppliers in this category sell three shapes of product that are easy to confuse:
| Format | What you receive | Who closes the safety case | Typical use |
|---|---|---|---|
| Enclosed adapter (wall-plug or desktop) | Finished, cased, marked product | The supply maker | Peripheral powered from an outlet |
| Open-frame board | Bare PCBA on standoffs, no cover | You, as the end-product maker | Equipment with its own housing |
| Built-in module | Board with partial cover, bracket or shield, sized for one host product | Shared — the module is designed around your host | Projectors, signage, kiosks, instruments |
Lexiang Power, a Shenzhen-fronted maker with its plant in Yichang, Hubei, lists 5–240 W open-frame PCB assemblies "for equipment makers who integrate the supply into their own enclosure," and separately 90–200 W projector built-in modules. The distinction between those two lines matters at the RFQ stage: an open-frame board is a catalogue part you adapt to, while a built-in module is usually engineered around a host's outline, connector positions and thermal path, with the volume commitment that implies.
Because the board has no case, four things you would never think about on an adapter become live:
- Accessibility. Mains-side parts are exposed. Your enclosure must prevent finger and tool access under the accessibility probes in the safety standard.
- Fire enclosure. A bare board relies on the host enclosure to be the fire barrier. Plastic housings need a suitable flammability rating; ventilation openings under and around the board have size and position limits.
- Thermal. The board's rated output assumes an ambient measured at the board, not in the room. Your enclosure sets that ambient.
- EMC. The board's own emissions were measured on a reference test set-up. Your cable routing and metalwork can raise or lower them.
The documents to ask for before you design the mounting
Do not start from a photograph of the board. Ask for the following, and treat any item that arrives as a PDF drawing with dimensions as a specification, and any item that arrives as a marketing sheet as a hint.
- Outline drawing with mounting-hole pattern. Hole diameter, centre-to-centre spacing, and the position of the tallest components relative to the holes. Common footprints in the industry follow inch-based conventions — 2 × 4 in, 3 × 5 in and 4 × 6 in boards with holes near the corners — but there is no rule forcing a supplier to follow them. Lexiang's page does not publish outlines per model; ask for the drawing of the exact wattage tier you intend to buy and confirm whether the same outline is held across the tier.
- Component height map. The highest points are typically the bulk electrolytic capacitor, the transformer and any heatsink. Their height sets your lid clearance and, if a heatsink is live (some are tied to a switching node), also sets a clearance you must respect from grounded metal.
- Connector part numbers and pinout. Mains input header, output header, any signal pins (remote on/off, power-good, fan output, 5 V standby). Know the mating connector before you order harnesses.
- Derating curve. Output power versus ambient, with the ambient point defined, and separate curves for natural convection and forced air if both are supported.
- Mounting orientation constraints. Some boards are rated for horizontal mounting only, with a lower rating vertical, because convection over the heatsink changes.
- Safety file type and its conditions of acceptability. Covered below.
- Hi-pot and ground-bond test values applied at the factory so you can repeat a compatible test on the finished product.
Reading the derating curve honestly
A derating curve is the most misread document in the open-frame trade. The typical shape is a flat line at 100% output up to some ambient — often in the 40–50 °C region for a convection-cooled board — then a straight-line fall-off to a lower percentage at the maximum permitted ambient. With forced air over the board, the flat section extends further and the maximum permitted ambient rises. The precise numbers are model-specific and Lexiang does not publish them on the page; ask for the curve for your model and for the airflow condition it was measured under.
What buyers get wrong:
- "Ambient" on the curve is not room temperature. It is the air temperature at the board, inside your enclosure. A sealed plastic housing with a 100 W board inside can run 20–30 °C above the room. If the room is 35 °C, the board may be seeing 60 °C, and at 60 °C the curve may permit only a fraction of nameplate output.
- Forced-air curves assume a stated linear airspeed across the board, and the direction matters — across the heatsink fins, not across the transformer. A fan on the far side of the enclosure that moves air around the board rather than over it does not put you on the forced-air curve.
- The curve is drawn at rated input voltage. At low line — say 90 V AC on a universal-input board — the primary current is higher and losses rise. If your product ships to markets with poor supply voltage, ask whether the curve holds at 90 V or only at 115/230 V.
- Electrolytic capacitor life is the real limiter. The rule of thumb electronics engineers use is that capacitor life halves for every 10 °C rise at the component. A board that is thermally within spec but running its bulk capacitor at 95 °C will not last as long as one running at 75 °C. Ask for the temperature-rise data of the bulk capacitor at your operating point, and ask whether the capacitor is 105 °C-rated and what hour rating it carries.
The acceptance test experienced integrators run: mount the board in a production-representative enclosure, run it at actual load in a thermal chamber at your maximum specified ambient, and thermocouple the bulk capacitor, transformer core and main heatsink. Compare against the supplier's stated maximum component temperatures. This catches an enclosure that is fine on the bench and marginal in a summer warehouse.
Creepage, clearance and what your chassis does to them
The board was designed with creepage and clearance distances between mains and secondary sides that satisfy the safety standard for its own geometry — for a 230 V system, reinforced isolation on the order of several millimetres of clearance and somewhat more creepage, the exact figures depending on pollution degree and PCB material group. The moment you mount the board, you add new surfaces: standoffs, the chassis floor, screw heads, a lid, a neighbouring board.
Three questions to settle on the drawing:
- Standoff height. The supplier's drawing should state a minimum standoff height so that solder joints on the underside of the primary side keep their clearance to a conductive chassis. Six to ten millimetres is common, but use the stated figure.
- Screw heads and washers at the mounting holes. If a mounting hole sits inside the primary area, the metal screw becomes a primary-side conductor and must maintain clearance to secondary traces and to accessible metal. Some boards use a slotted or isolated hole for exactly this reason; check whether yours does.
- Earthing. A Class I board expects its protective-earth point to be bonded to your chassis with a low-resistance path. A Class II board does not need it but may have a functional earth for EMI that you must not treat as protective earth. Get the class in writing.
If your enclosure's environment is damp, dusty or subject to condensation — outdoor signage, commercial kitchens, industrial floors — an unprotected open-frame board is a poor fit. The options are a conformal coat or a potted variant, and the trade-offs of each are covered in the guide to conformal coating, potting and box-build in China. A coating changes the board's thermal behaviour slightly and changes its safety file, so decide before the safety file is opened, not after.
Component-level versus end-product-level safety files
This is the item most first-time integrators discover late. A safety certification body can issue one of two kinds of file for a power supply board:
- A component-level file (a "recognised component" in North American terminology, often with a conditions-of-acceptability document attached) says the board meets the relevant requirements when installed in accordance with the stated conditions. The conditions typically specify maximum ambient, mounting orientation, the need for a fire enclosure, the need for a specific fuse or earth connection, and sometimes the maximum permitted output load in the end product. Your finished equipment is then evaluated with the board treated as a pre-approved sub-assembly, and the reviewer checks that you met the conditions.
- An end-product-level file says the item is complete and safe as sold. That is what an enclosed adapter carries. A bare board almost never has one, because a bare board is not a complete product.
With a component-level file and a clear conditions document, your own product's safety evaluation is shorter and cheaper, because the reviewer accepts the board's construction. Without any file, the reviewer evaluates the board as part of your product, at your cost and on your schedule. Ask which of these you are getting for the model you want, ask for the conditions-of-acceptability document, and check on the certificate itself the issuing body, the holder's legal name and the validity date. Lexiang's page states that certification is granted per model and tells you to ask for the one covering yours; it does not publish which of its open-frame models carry which file type, so that is an RFQ question, not a catalogue assumption.
One further check: the holder name. Lexiang operates through two companies — a manufacturing entity in Yichang and a commercial entity in Shenzhen. A file held by one entity while your invoice comes from the other is not a defect, but your own certification body will want the chain documented. Ask early.
EMC: the board's report is not your report
An open-frame board's emissions test was run with a defined test set-up — a reference load, specified cable lengths, a particular grounding arrangement. When you install the board, three things change the result:
- Output cable length and routing. Long unshielded DC leads inside a metal enclosure act as antennas for switching noise. Twisting the pair and keeping it away from the mains inlet usually helps; running it parallel to the AC lead usually hurts.
- Earth path. On Class I boards, the impedance of the earth path from the board's PE point to the inlet earth pin affects conducted emissions through the Y-capacitors. A long thin earth wire is a common cause of a marginal fail at low frequency.
- Load character. A motor drive or a switching load on the output can push noise back into the supply that the reference resistive load never did.
Budget for an EMC pre-scan of the finished product with the board installed, and ask for the board-level test report so you know the starting margin. If the board sits within a few dB of the limit, assume your enclosure will consume that margin.
Insider details worth writing into the purchase order
- Inrush current at cold start. Boards in the 100–240 W class with active power-factor correction draw an inrush pulse when first energised. If your product has several supplies or a mains switch that closes at peak, breakers trip. Ask for the inrush figure at 230 V and whether an NTC or active limiter is fitted.
- Standby and no-load behaviour. If your product has a soft-off state, the board's no-load consumption is your product's standby figure. Ask for the measured no-load input power and whether a remote-off pin exists.
- Hold-up time. The number of milliseconds the output stays in regulation after mains is lost. Matters for anything with a processor that must shut down cleanly. It is set by the bulk capacitor and drops at low line.
- Lot-level test records. Lexiang lists in-process combined testers and automated burn-in racks on site. Ask whether burn-in duration and temperature for open-frame boards are the same as for enclosed products, and whether the lot record can travel with the shipment.
- Reference to the enclosed sibling. If the supplier builds the same power stage in a desktop enclosure, the enclosed version's thermal data is a useful sanity check for your own housing. For battery-fed equipment, the CC/CV question covered in the piece on desktop adapters in power mode versus charging mode applies to open-frame boards too — a board that feeds a pack directly needs a charging profile, not a fixed output.
What to ask the supplier next
Put these into the RFQ alongside your electrical spec — the product spec sheet format that a factory can quote against without guessing.
- Send the outline drawing, hole pattern and height map for the exact model, and state whether the outline is common across the wattage tier.
- Send the derating curve with the ambient reference point, the airflow condition, and the input voltage it was drawn at.
- State the maximum component temperatures for the bulk capacitor, transformer and main heatsink, and the capacitor's temperature and hour rating.
- State the minimum standoff height, the mounting orientation permitted, and the safety class (I or II), with the earth point identified.
- State the safety file type — component-level with conditions of acceptability, or end-product — and provide the certificate showing issuer, holder name and validity.
- Provide the EMC test report with the test set-up described, so your integration team knows the starting margin.
- State inrush current, hold-up time, no-load power and any signal pins available.
- Confirm which legal entity contracts, invoices and holds the file.
Lexiang Power is a reasonable example of the profile to evaluate for this kind of purchase: a maker that lists 5–240 W open-frame PCB assemblies alongside 90–200 W projector built-in modules, with wave soldering, burn-in and environmental chambers on site, and a factory page that already tells you to check certification per model rather than per company. Read the factory profile with the eight questions above in hand; the drawing and the derating curve are the deliverables that let you design the enclosure, and nothing on a catalogue page replaces them.