Search for a desktop power adapter in charging mode with CC/CV versus a fixed-output brick and you will find two products that look identical on the outside: the same black case, the same C14 or C8 inlet, the same barrel or 4-pin DIN plug on a 1.2 m lead. The difference is entirely in what the output does when it meets a battery. A fixed-output supply holds its voltage and lets the load decide the current. A charging-mode supply holds the current first, then the voltage, and tells the user through an LED when it has finished. Order the wrong one and the failure will not show up on your bench — it shows up in the field, as a pack that never reaches full charge, a supply that hiccups every time the tool is switched on, or a return that the repair shop cannot reproduce.

This article walks through what changes inside the brick, which product types belong in each column, what the status LED is actually reporting, and what has to be on the spec sheet before a supplier can quote either version correctly.

What "power mode" and "charging mode" mean inside the case

A desktop adapter in power mode is a regulated constant-voltage source. Set for 24 V, it delivers 24 V from no load up to its rated current, and beyond that it enters a protection state — typically current limit, hiccup or shutdown, depending on the design. It does not care what the load is. A motor controller, a router, a display and a fully charged battery all look the same to it: a resistance drawing some amperes.

A desktop adapter in charging mode is a constant-current / constant-voltage source. Connected to a discharged pack, it first clamps the current at a set value (the CC phase) while the pack voltage rises. When the pack reaches the set voltage ceiling, the supply switches to holding that voltage (the CV phase) and the current tapers as the cells fill. Somewhere on the taper — at a current threshold, after a timer, or on an external signal — the supply declares the charge complete and changes the LED. That tapering, the declaration, and the behaviour when a pack is reconnected are the whole product.

Manufacturers in this category commonly build both behaviours on one mechanical platform. Lexiang Power, a Shenzhen-fronted power supply maker with its plant in Yichang, Hubei, lists its 90–150 W and 120–240 W desktop bricks in exactly those two versions — power mode with a fixed output, and charging mode with CC/CV control and a charge-status LED — for battery-powered equipment that wants the same footprint either way. That is convenient for a buyer whose range includes both mains-powered and battery-powered SKUs, but it also means the two versions can be confused on a purchase order. Put the mode on every line item, not just in the drawing.

Which one your product needs

The test is simple: does the supply's output connect directly to battery cells, or to something that manages the cells?

Your product's power architecture Order this Why
Battery pack with its own charge controller or BMS that regulates charge current Power mode (fixed output) The controller does CC/CV; the brick only needs to deliver stable voltage headroom
Battery pack connected to the DC input with only protection (fuse, PTC, protection-only BMS) Charging mode (CC/CV) Nothing else limits the current; the brick must
No battery — motor, lighting, networking, medical or lab equipment Power mode There is nothing to charge
Product runs from the brick while the battery charges from an internal charger Power mode, sized for load plus charge current The internal charger sets the profile; the brick must cover both draws at once
Standalone charging cradle or dock with no electronics beyond a connector Charging mode The cradle is a cable; the brick is the charger
Sealed lead-acid (SLA) equipment — mobility, floor care, backup — with no onboard charger Charging mode with float stage SLA wants a bulk/absorb/float profile, not a Li-ion cut-off

Two mistakes are common enough to name.

The first is powering a bare pack from a fixed-output brick because "the voltage matches." It does not stay matched. A 24 V nominal Li-ion pack at 30% state of charge sits well below its 29.4 V full voltage; a 29.4 V fixed supply connected to it will try to source whatever current the pack impedance allows, hit its own current limit, and go into hiccup. The user sees a flickering LED and a pack that charges erratically. The brick is not defective; it was never a charger.

The second is the reverse: charging mode for a product with its own BMS. Two controllers fight; the BMS throttles current, the brick reads the drop as the CV taper and declares the charge finished at 80%.

What changes in the spec sheet

Once the mode is settled, the spec sheet for a charging-mode brick needs fields that a fixed-output brick does not. These are the ones that decide whether a supplier can quote at all, and this is where you should not assume the factory's catalogue defaults match your pack. Lexiang's page states the two behaviours but does not publish supported chemistries, cell counts or termination logic — treat those as questions to ask, not values to assume.

For a fixed-output brick, the essentials are:

  • Output voltage and tolerance at the connector (say ±5%, or tighter if your load needs it)
  • Rated continuous current, and the peak/duration your load draws at start-up
  • Protection behaviour on overload: latch-off, auto-recovery hiccup, or fold-back — and what resets it
  • Ripple and noise measured under the industry convention (20 MHz bandwidth, with a 0.1 µF ceramic and a 47 µF electrolytic across the output at the cable end) — a figure without the measurement condition is meaningless
  • Connector type, polarity and cable length

For a charging-mode brick, add all of these:

  • Battery chemistry and configuration: Li-ion or Li-polymer (3.6/3.7 V nominal, typically 4.2 V per cell full), LiFePO4 (3.2 V nominal, 3.6–3.65 V full), or SLA (2.0 V nominal per cell, with a float voltage around 2.25–2.3 V per cell). The series cell count then sets the CV voltage
  • CC current, and whether a lower pre-charge current is needed when the pack is deeply discharged below its normal window
  • Termination: at what fraction of CC current the charge is declared complete (C/10 and C/20 are the two most common conventions), whether a safety timer backs it up, and what happens after termination — full stop, or trickle/float
  • Restart behaviour: does the charger resume automatically when the pack voltage sags below a re-charge threshold, or only when re-plugged
  • LED logic: colour for charging, colour for complete, and — the one everyone forgets — what the LED does on a fault, with no pack connected, and with a reverse-connected pack
  • Whether the pack has a thermistor and whether the charger reads it; whether any sense line, wake pin or serial signal is expected on the connector

A useful discipline is to write these into the same document you would use for any component you hand to a Chinese factory — the spec sheet format that a factory can quote against — rather than in an email thread. The CC current and the CV voltage are numbers that will be set in firmware or by resistors on the control board, and a supplier that quotes from a one-line description has guessed both.

The status LED: what it is reporting and what it cannot know

The charge-status LED on a desktop brick is driven by the supply's own control loop, not by the battery. That distinction explains most complaints about "the light says full but the battery isn't."

What the supply can observe is its own output current and voltage. It declares "complete" when the CV-phase current falls below the termination threshold. Three things make that signal lie:

  1. A load running in parallel with the pack. If the product draws 300 mA while sitting in its dock, the supply's current may never fall below a C/10 threshold set at 250 mA — the LED stays red forever on a full battery. Or, if the load is intermittent, the LED toggles. The fix is either a higher termination threshold agreed with the supplier, a timer backstop, or moving termination inside the product where the pack current is actually measured.
  2. A BMS that opens the charge FET. When a pack's protection circuit disconnects at over-temperature or cell imbalance, the supply sees zero current and reports "full." The pack may be at 40%.
  3. A pack with a small trickle or float stage. Some SLA profiles hold a float current indefinitely; the supply must know to treat that as complete rather than as still-charging.

None of these are supplier defects. They are architecture decisions you make, then communicate. One more check on any sample: with no pack connected, a charging-mode supply sits at its CV voltage with negligible current, so a naïve implementation shows "complete" on an empty connector.

Why the same wattage costs and tests differently in charging mode

A 120 W fixed-output brick and a 120 W CC/CV brick share the power stage, the transformer and the case. They do not share the control board, the test plan, or — in many markets — the regulatory path.

Control. Charging mode adds a current-sense element and a second control loop, plus the logic for termination, timer and LED. Expect a new-profile request (different chemistry, different cell count) to be treated as an engineering variant with its own sample round, not a parameter change.

Testing. A fixed-output brick is tested at rated load and at overload. A charging-mode brick has to be tested through the full profile — CC phase, transition, taper, termination, restart — and at temperature extremes, because the CV set-point of a lithium charger is a safety-relevant number: a few percent high is an overcharge condition, not a tolerance issue. Lexiang's page lists automated burn-in racks and high/low-temperature chambers on site; whether charging-mode units are burned in against a simulated pack, and for how long, is not published — ask.

Regulatory. In North America a desktop adapter sold as a battery charger for a consumer product can fall under the Department of Energy's battery-charger efficiency rule (10 CFR 430, subpart B, Appendix Y test procedure) rather than the external-power-supply rule, with a different test method and a different marking. California's appliance-efficiency regulation has its own battery-charger requirements. The safety file — UL 1310 Class 2 for low-voltage limited outputs, or UL/IEC 62368-1 for the general case — should name the model in the mode you are buying. All of these are things you require the supplier to demonstrate for your exact model; the general process for sorting out which approval applies to which market is covered in the CE, FCC and product-certification guide. Above roughly 75 W input, EU harmonic-current limits under EN 61000-3-2 also push designs toward active power-factor correction — which is why a 120–240 W desktop supply is physically larger per watt than a 45–65 W one, in either mode.

Insider details that separate a working order from a returns pile

A few things that experienced buyers of desktop bricks write into the order and that first-time buyers discover later:

  • Backfeed protection. When a pack is connected and the mains is removed, the pack will try to push current back into the supply's output stage. A fixed-output brick without a blocking diode or ideal-diode circuit can glow its LED from the battery, and in some designs slowly drain the pack. Specify reverse-current blocking and ask how it is implemented.
  • Hot-plug arc on the DC connector. Plugging a live CV output into a discharged pack draws a large inrush through the connector contacts. On barrel jacks that pits the contacts; on 4-pin DIN connectors it can weld pins over a few hundred cycles. Charging mode with a soft-start on connection, or a connector rated for the current with make-first/break-last ground, solves it — but only if somebody asked.
  • Cable drop. A 1.8 m output lead at 5 A drops enough voltage that the CV set-point measured at the brick is not the voltage at the pack. Ask whether the CV voltage is regulated at the connector end (remote sense) or at the board, and add the cable resistance into your set-point request if it is the latter.
  • Two entities on the paperwork. Lexiang Power, like many Chinese power-supply makers, operates through a manufacturing company in Yichang and a commercial company in Shenzhen. The factory page itself says to ask which entity will sign your contract, issue your invoice and appear on your certificates. For a charging-mode product, where the safety file names the specific charge profile, the holder name on that file has to match the entity you are contracting with.

What to ask the supplier next

Work through this list before you request samples. The answers decide the quote, and any item marked "not published" on the supplier's page is an item you must get in writing.

  1. Confirm the mode on every SKU. "Desktop supply, 24 V, 5 A, power mode" or "charging mode, 7S Li-ion, 29.4 V CV, 4.0 A CC" — the mode is part of the part number, not a note.
  2. Ask which chemistries and cell counts the charging-mode platform supports and whether your profile is a catalogue variant or a new development with its own sampling round and tooling of the control board.
  3. Ask for the termination criterion and timer in numbers: threshold current, timer duration, restart threshold voltage.
  4. Ask for the LED truth table: state of the LED for charging, complete, no pack, fault, reverse polarity and over-temperature.
  5. Ask whether the connector carries anything besides power — a thermistor line, a wake pin, a sense pair — and whether the factory's charging-mode units can read or drive it.
  6. Ask how charging-mode units are burned in and end-of-line tested — against a resistive load, an electronic load, or a battery simulator — and whether the lot test record can be released with the shipment.
  7. Ask for the safety and efficiency file that names your model in your mode, and check the issuing body, the holder name and the validity date on the document itself rather than on a badge.
  8. Ask which legal entity is the contracting party, the invoicing party and the certificate holder, and get all three in the same email.

Lexiang Power is a workable example of the profile to look for in this category: a maker whose 90–150 W and 120–240 W desktop range is built in both power mode and charging mode on one mechanical platform, with on-site burn-in and environmental chambers, and a factory page that already tells you to verify the entity and the certificate per model before you commit. Read the factory profile with the questions above in hand — the answers you get to items 2 through 6 are the specification, and nothing on a catalogue page substitutes for them. If your product is a USB-C device rather than a barrel-fed pack, the same discipline applies at the negotiation layer instead; see the companion piece on PD output profiles, PDOs and PPS.