Constant-current versus constant-voltage LED driver selection in the 12–36 W band comes down to one line on your LED module's datasheet. If the module lists a forward current (say 700 mA) and a forward voltage range (say 24–34 V), it wants a constant-current driver. If it lists a supply voltage (12 V or 24 V) and a power per metre or per module, it already regulates its own current and wants a constant-voltage driver. Get this backwards and one of two things happens: a CC driver on a CV module pushes its voltage up to the open-circuit clamp and either overdrives the first module or trips; a CV driver on a bare CC module has nothing limiting the current and the LEDs run away thermally in seconds.

That is the short answer. The long answer — which drives which choice, what a high-power-factor variant buys you, and what to demand from a driver supplier — is below.

What each driver type actually regulates

An LED is a diode: its current rises steeply once its forward voltage is exceeded, and its forward voltage falls as it heats up. Left to a fixed voltage, a string of LEDs draws more current as it warms, which heats it further. Something has to hold the current. The only question is whether that something is in the driver or on the module.

Constant-current (CC) driver. The driver holds output current at a set value — 350, 500, 700, 1050 mA are common steps — and lets the output voltage float within a stated compliance window to whatever the string needs. The datasheet reads "700 mA, 24–36 V." Your string's total forward voltage must fall inside that window across its full temperature range. Below the window, many drivers cannot regulate; above it, the driver hits its voltage clamp and current falls.

Constant-voltage (CV) driver. The driver holds voltage — 12 V or 24 V almost universally in this power band — and the module carries its own current regulation: series resistors on flexible strip, a linear regulator on better strip, or a small buck stage on modules for signage. The driver's datasheet reads "24 V, 1.5 A max." Your job is to keep total load under the rated current and to manage voltage drop along the cable.

Suppliers in this band build both. Lexiang Power, a Shenzhen-fronted power supply maker with its plant in Yichang, Hubei, lists 12–36 W constant-current and constant-voltage drivers for LED modules and fixtures, in wall-plug and desktop formats, including high-power-factor variants. Two things about that listing matter for selection: the wall-plug format means a driver that plugs straight into an outlet, which limits it to Class II low-voltage applications and rules out anything that needs hard-wiring into a fixture; and the high-power-factor variant is a separate product with a different front end, not a firmware option on the standard driver.

A selection matrix you can put in front of your engineer

Your load Driver type Why Watch for
Single COB or LED array with stated forward current and Vf range CC The array has no current control of its own Vf window across cold-start and hot; open-circuit clamp voltage
Several identical modules in series CC One current through all; forward voltages add Sum of Vf must stay within the driver's window at both temperature extremes
Modules in parallel with no per-string balancing Neither, without redesign Strings share current unequally as they heat Add per-string resistors or use one CC channel per string
Flexible LED strip, 12 V or 24 V, with on-strip resistors CV Strip self-limits current Voltage drop over length; strip power per metre × length ≤ driver rating with margin
Signage modules with on-board regulator, 12 V CV Module regulates Inrush from many modules' input capacitors; driver minimum load
Retail display or light box with mixed strip lengths CV Runs are unequal and change at install Total load unknown at order time — size for maximum configuration
Fixture that must dim from a wall dimmer CC or CV with matching dimming interface Dimming method is a driver attribute, not a load attribute TRIAC vs 0–10 V vs PWM is an ordering line item

Two rows deserve emphasis. Modules in parallel without balancing are the single most common field failure on CC systems: the string with the lowest forward voltage takes the most current, warms, drops its voltage further, takes more current, and fails first — after which the remaining strings share the same total current and follow it. A driver cannot fix this; the module design has to.

For CV systems, the trap is minimum load. Some CV drivers need a small load to regulate cleanly; with a very short strip, output can ripple or the driver can enter burst mode and the strip flickers visibly. Ask the supplier for the minimum-load figure, not just the maximum.

What high power factor buys you — and when you must have it

Power factor is the ratio of real power to apparent power drawn from the mains. A standard small driver rectifies the mains into a bulk capacitor and draws current in short spikes near the voltage peak; power factor can sit around 0.5–0.6, and the current waveform is rich in harmonics. A high-power-factor (HPF) driver adds a stage — usually a boost converter or a single-stage topology that shapes input current — to draw a near-sinusoidal current, pushing power factor toward 0.9 or above.

What you get for the extra stage:

  • Regulatory access. In the EU, EN 61000-3-2 places lighting equipment above 25 W input in Class C, with harmonic-current limits that a non-PFC driver generally cannot meet. Below 25 W the requirements are relaxed, which is why a 12 W wall-plug LED adapter can be a simple design and a 36 W hard-wired driver usually cannot. In North America, utility rebate and listing programmes for commercial lighting — the DesignLights Consortium and Energy Star among them — set power factor thresholds, commonly 0.9, for qualifying products. If your fixture will chase those listings, the HPF variant is the only option.
  • Lower apparent current. A 36 W driver at 0.55 power factor draws about 65 VA; at 0.95 it draws about 38 VA. On a circuit running dozens of fixtures, that difference decides how many you can put on one breaker.
  • Less flicker in some topologies, more in others. This is the part buyers get wrong. A single-stage PFC driver without a large output capacitor can produce output ripple at twice the mains frequency (100 or 120 Hz), which shows up as flicker on camera and in some people's perception. A two-stage PFC driver with a proper output filter does not. Ask for the driver's percent flicker and flicker index at full output, and — if the fixture will be used in offices or on video — compare against the IEEE 1789 recommended-practice ranges.

What HPF does not buy you: efficiency. The extra stage costs a few percent. A buyer who orders HPF for "quality" reasons on a residential wall-plug product that never needs it is paying for heat.

Lexiang's page lists HPF variants but publishes no power-factor figure or harmonic test result for them. That is normal for a catalogue page and not a red flag; it means the figure is an RFQ line, and the answer you want is a measured value at your load, at both 120 V and 230 V, not a generic ">0.9".

Dimming, ingress protection and the safety class: three ordering lines that are not on the module datasheet

Dimming. Whether a driver dims and by what method is entirely a driver attribute. Phase-cut (TRIAC / leading-edge, or ELV / trailing-edge) dimming works from a standard wall dimmer but needs a driver designed to hold the dimmer's minimum current and to avoid flicker at low settings; compatibility is tested against a list of named dimmers, and that list is something to request. 0–10 V dimming needs two extra wires and a control signal from the building; PWM dimming is for controllers that already have a logic output. "None" is a valid answer and is the cheapest. Do not assume a driver dims; ask, and ask for the compatible-dimmer list.

Ingress protection. A wall-plug LED adapter is an indoor, dry-location product by construction. For a damp-location fixture — bathroom mirrors, under-cabinet lighting near a sink, covered outdoor signage — you need a driver with a stated IP rating, and for wet locations typically a potted driver. Potting changes the thermal path (usually for the better), the weight, the ability to repair (none), and the safety file. Lexiang's page does not list IP ratings or potting for its driver range; if your application is anything other than dry indoor, that is a question for the supplier. And if you plan to build a bare driver board into your own fixture housing instead of buying a cased unit, the creepage, standoff and derating rules in the piece on integrating open-frame power boards into your own enclosure apply to a driver exactly as they do to any other supply.

Safety class and Class 2 output. In North America, a driver whose output is limited to 60 V DC and 100 VA can be a Class 2 power unit under UL 1310, which lets the low-voltage wiring on the load side be installed without the protection required for mains wiring — a large installed-cost saving for strip and signage. In the 12–36 W band this is achievable, but only if the driver is designed and certified to it. For the fixture as a whole, UL 8750 covers LED equipment and IEC/EN 62368-1 or the lighting-specific standards apply in other markets. These are things you must require the supplier to demonstrate for your model; the general shape of getting a product certified for each destination is covered in the CE, FCC and product-certification guide, and the light-box and display context specifically in the LED-lit acrylic display design guide.

Insider details that catch first-time buyers

  • CC drivers have an open-circuit voltage clamp. With no load — during installation, or if a string fails open — a CC driver's output rises to a clamp, often well above the working range. If that clamp exceeds a Class 2 limit, the product cannot be Class 2 regardless of normal operating voltage. Ask for the open-circuit voltage.
  • "Current tolerance" on a CC driver means something different from "voltage tolerance" on a CV driver. A ±5% current tolerance on a 700 mA driver is ±35 mA, which is a visible brightness difference between two adjacent fixtures. Tighter tolerance bands cost more and are worth it for linear runs where fixtures sit side by side. Lexiang's page does not publish current steps or tolerance bands; request both.
  • Inrush on CV systems multiplies. Every 12 V signage module carries an input capacitor. Fifty modules on one driver draw a combined inrush that can exceed the driver's start-up current limit and cause it to hiccup. Ask whether the driver has a soft-start, and derate the module count if it does not.
  • Thermal reference point. Driver datasheets rate at a case temperature (often marked as a "tc" point on the housing), not room ambient. A driver rated to 80 °C tc inside a sealed ceiling fixture in a warm climate can spend its life near that limit. Ask for the tc point location and the lifetime claim at that temperature — and, as with any power supply, expect that lifetime to be governed by the electrolytic capacitor. Lexiang lists high/low-temperature chambers and automated burn-in racks on site; ask whether driver burn-in is run at elevated ambient and for how long.
  • Wall-plug drivers and fixture markets rarely mix. A plug-in LED module adapter is a consumer or display product. A fixture manufacturer in the commercial-lighting business — the market covered in the high-bay LED supplier guide — will want a hard-wired, HPF, dimmable, IP-rated driver with terminal blocks. If a supplier's range is mostly wall-plug and desktop formats, confirm early that the hard-wired variant you need exists as a real model rather than as a promise.

A selection procedure you can run in an afternoon

  1. Take the module datasheet and circle one of two things: forward current plus Vf range (CC), or supply voltage plus power (CV). That decides the driver type.
  2. For CC: add the forward voltages of everything in series at the lowest expected temperature (highest Vf) and at the highest (lowest Vf). Both totals must sit inside the driver's compliance window with margin. Pick the current step that matches the module's rating or the derated point you have chosen for lifetime.
  3. For CV: multiply strip or module power by quantity, add 20% for margin and for the fact that strip is often brighter than rated when new, and pick a driver above that. Check cable length against the strip's voltage-drop table; if a 24 V option exists, prefer it over 12 V for anything over a couple of metres.
  4. Decide dimming — none, phase-cut, 0–10 V or PWM — and write it on the order.
  5. Decide the location rating — dry, damp, wet — and whether potting is required.
  6. Decide whether HPF is required by regulation (EU > 25 W lighting, or a listing programme) or by circuit loading. If neither, do not pay for it.
  7. Decide the safety route — Class 2 output, fixture-level approval, or both — and write the standard on the RFQ.

What to ask the supplier next

  1. Ask for the CC current steps offered and the tolerance band on each, and for the open-circuit clamp voltage.
  2. Ask for the CV minimum load and the output ripple at minimum and maximum load.
  3. Ask for the measured power factor and harmonic-current result on the HPF variant at your load and at 120 V and 230 V, with the test report.
  4. Ask for the dimming method and the compatible-dimmer list, or a written statement that the driver is non-dimming.
  5. Ask for the IP rating and whether a potted version exists for the wattage tier you need.
  6. Ask for the tc point location, the maximum tc, the lifetime claim at that tc, and the capacitor's temperature rating.
  7. Ask for the safety certificate covering your exact model, and check the issuing body, the holder's legal name and the validity date on the document itself — not on a badge.
  8. Ask which legal entity will sign, invoice and hold the file, because the maker's own page tells you there are two.

Lexiang Power is a workable example of the profile to test these questions against: a maker whose 12–36 W driver range spans both CC and CV in wall-plug and desktop formats with HPF variants, with environmental chambers and burn-in on site, and a factory page that states certification is granted per model and tells you to ask for the one covering yours. Read the factory profile with the list above in hand — the current steps, the tolerance band, the power-factor measurement and the dimming list are the specification, and none of them is on a catalogue page.